Making a difference to the people we help treat by creating value and improving healthcare outcomes through connecting innovative manufacturers with Australasian customers.

Theradiag LISA TRACKER for determination of ustekinumab in Crohn’s disease

Products are for professional/laboratory use only.

Ustekinumab Serum Trough Levels May Identify Suboptimal Responders to Ustekinumab in Crohn’s Disease. Painchart C, Brabant S et al; Dig Dis Sci. 2019 Oct 10.

Abstract

Aim
The aim of this study was to evaluate the association between serum ustekinumab (UST) trough levels and response to induction and maintenance UST treatment in refractory Crohn’s Disease (CD) patients.

Methods
We performed a prospective study including CD patients who received UST from September 2015 to January 2017. Patients received 90 mg of UST subcutaneously at weeks 0, 4, and 12, then every 8 weeks. Two cohorts of patients were analyzed: an induction cohort and a maintenance cohort. We evaluated clinical, biological, and imaging/endoscopic response to UST treatment. UST trough levels and anti-UST antibodies were dosed at weeks 12 and 28 in the induction cohort, and at a single time point in the maintenance cohort.

Results
Forty-nine patients were enrolled in the maintenance cohort. Mean concentrations of UST were 1.88 ± 1.40 μg/mL. UST trough levels were not significantly different in patients with or without clinical, biological, or imaging/endoscopic responses to UST treatment (p > 0.11). Twenty-three consecutive patients were included in the induction cohort. At week 12, mean UST concentrations were 1.45 ± 1.15 μg/mL. Patients with a biological response to UST treatment had significant higher serum UST trough concentration (median 1.72 μg/mL) than non-responders (median 0.56 μg/mL, p = 0.02). A UST  trough level ≥ 1.10 μg/mL at week 12 was associated with a biological response to UST treatment at 6 months.

Conclusion
UST trough levels were associated with a biological response at the end of the induction phase. In patients with low levels of UST, optimization treatment may be necessary to obtain a sustained response.

Read Abstract

Pubmed>

Discover Theradiag LISA TRACKER

Click Here >

Request a quote

Contact Us >



Request a Quote

Request Quote

Recent Posts

Immuno Concepts: PSITS Program 2026

The Immuno Concepts Patient Sample Interpretative Training Series (PSITS) is a program designed as a teaching and training tool for laboratory staff to enhance their knowledge in…

Read full article

Thermo Fisher – Phadia Quality Controls Guide

Why Quality Controls Matter in Allergy and Autoimmune Diagnostics In clinical laboratories, the accuracy of diagnostic results is of utmost importance, particularly when managing complex…

Read full article

Thermo Fisher – Spring Allergy Range

Setting the Standard in Allergy Diagnostics In the evolving landscape of allergy diagnostics, precision and reliability are paramount. Thermo Fisher Scientific’s ImmunoCAP™ product range stands…

Read full article